| Alternative NSN: 4130-00-352-0534 |
| Item Name: Chiller Water Refrigerating |
| FSG: 41 Refrigeration Air Conditioning and Air Circulating Equipment |
| Federal Supply Class (FSC): 4130 Refrigeration and Air Condition Components |
| NIIN: 003520534 |
| NCB Code: USA (00) |
| Manufacturers: Hartford Compressors Inc |
Browse NSN parts of NSN 4130-00-352-0534 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 4130-00-352-0534 like HX15M1 described as Chiller Water Refrigerating from industry leading manufactures such as Hartford Compressors Inc. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
| Part No | Manufacturer | Item Name | QTY | RFQ |
|---|---|---|---|---|
| HX15M1 | Hartford Compressors Inc | chiller water refrigerating | Avl | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABMK | Overall Width | 5.875 INCHES NOMINAL |
| AWGH | Tube Type | COILED |
| AWKW | Water Connection Type | PIPE |
| AWLB | Refrigerant Outlet Connection Quantity | 1 |
| AWCD | Water For Which Designed | FRESH |
| AWCK | Refrigerant Operating Location | IN TUBES |
| AWKR | Shell Length | 9.688 INCHES |
| AWKS | Shell Outside Diameter | 6.750 INCHES |
| AWKY | Refrigerant Inlet Connection Type | TUBE |
| AWKZ | Water Connection Size | 1/4 IN. IPS |
| AWLD | Refrigerant Outlet Connection Size | 5/8 IN. |
| AWGF | Effective Cooling Area | 0.550 SQUARE FEET |
| MRC | Decoded Requirement | Clear Text Reply |
| AWGJ | Tube Material | COPPER |
| AWKT | Water Connection Quantity | 2 |
| AWKX | Refrigerant Inlet Connection Quantity | 1 |
| AWLA | Refrigerant Inlet Connection Size | 5/8 IN. |
| AWLC | Refrigerant Outlet Connection Type | TUBE |
| ADSM | Mounting Position | VERTICAL |
| ABHP | Overall Length | 10.312 INCHES NOMINAL |
| AEUG | Shell Material | ALUMINUM |
| AWWG | Refrigerant Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH |
| AWWH | Water Side Test Minimum Pressure | 225.0 POUNDS PER SQUARE INCH |
| ACKL | Media For Which Designed | FREON 12 |
|
4110-00-203-2706 (4110002032706) |
4110-00-222-2196 (4110002222196) |
4110-00-243-9823 (4110002439823) |
|
4110-00-243-9824 (4110002439824) |
4110-00-249-5373 (4110002495373) |
4110-00-255-8762 (4110002558762) |
|
4110-00-320-1087 (4110003201087) |
4110-00-351-9287 (4110003519287) |
4110-00-370-7959 (4110003707959) |
|
4110-00-393-4789 (4110003934789) |
4110-00-402-3220 (4110004023220) |
4110-00-492-4822 (4110004924822) |
Before You Go, Why Don’t You Take a Look at Our Aviation Parts Catalog.