NSN 5915-01-317-8633 (5915013178633) Listing

Alternative NSN: 5915-01-317-8633
Item Name: Filter Radio Frequency Interfere
FSG: 59 Electrical and Electronic Equipment Components
Federal Supply Class (FSC): 5915 Filters and Networks
NIIN: 013178633
NCB Code: USA (01)
Manufacturers: Filtronetics Inc, Raytheon Company, Sora Power Inc


Browse NSN parts of NSN 5915-01-317-8633 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5915-01-317-8633 like H960048-001B, FN788, 10B788 described as Filter Radio Frequency Interfere from industry leading manufactures such as Raytheon Company, Filtronetics Inc, Sora Power Inc. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.


Part Number's List for NSN 5915-01-317-8633, 5915013178633

Part No Manufacturer Item Name QTY RFQ
H960048-001B Raytheon Company filter radio frequency interfere Avl RFQ
FN788 Filtronetics Inc filter radio frequency interfere Avl RFQ
10B788 Sora Power Inc filter radio frequency interfere Avl RFQ

Product Specification of NSN 5915013178633

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH4.093 INCHES NOMINAL
ABKWOVERALL HEIGHT2.900 INCHES NOMINAL
ADAQBODY LENGTH3.750 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ+10.0/+2000.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.750 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-55.0/+100.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 5TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 3RD RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION200.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE
AHBNINPUT TERMINAL MANUFACTURER CODE96906
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNC
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TURRET GROUND 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION168.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQRGBODY MATERIALALUMINUM
CRSTBODY SURFACE TREATMENTTIN
PKWTUNPACKAGED UNIT WEIGHT3.500 POUNDS
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
ADATBODY WIDTH4.250 INCHES NOMINAL
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQJXNOMINAL THREAD SIZE0.138 INCHES
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION105.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY5 PIN OUTPUT 2ND FUNCTION
ADAUBODY HEIGHT2.200 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH3.250 INCHES NOMINAL
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS2.0 4TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 1ST RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS3.0 2ND RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION200.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
AHBPINPUT TERMINAL IDENTIFICATIONMS27656T16B97P
AHCGMAXIMUM TEMP RISE40.0 DEG CELSIUS
CBBLFEATURES PROVIDEDSHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR, RECEPTACLE INPUT 1ST FUNCTION
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE600.0 VOLTS AT SEA LEVEL

Browse More NSN for 5915-01-317-8633, 5915013178633

5905-00-001-2971
(5905000012971)
5905-00-001-3031
(5905000013031)
5905-00-001-3050
(5905000013050)
5905-00-001-3085
(5905000013085)
5905-00-001-3197
(5905000013197)
5905-00-001-3806
(5905000013806)
5905-00-001-3819
(5905000013819)
5905-00-001-3821
(5905000013821)
5905-00-001-3822
(5905000013822)
5905-00-001-3824
(5905000013824)
5905-00-001-3825
(5905000013825)
5905-00-001-3827
(5905000013827)

Frequently Asked Questions (FAQ): NSN 5915-01-317-8633

Who Are the Manufacturers We Source from Who Produce Items under NSN 5915013178633 ?
  • The manufacturers we source from for any items with the NSN 5915013178633 include those like Raytheon Company, Filtronetics Inc, Sora Power Inc.
What Part Numbers with the NSN 5915013178633 Are Available on ASAP Buying?
  • For those seeking solutions for items with the NSN 5915013178633 , our website currently features in-demand part numbers like H960048-001B, FN788, 10B788, both of which are listed with the product description .
What Is the National Codification Bureau (NCB) code and Country Associated with the NSN 5915013178633 ?
  • The National Codification Bureau (NCB) code for NSN 5915013178633 is USA (01) denoting that this item was initially codified by the United States.
How Are CAGE Codes Like 82577 Related to NSN 5915013178633 ?
  • The CAGE Code 82577 identifies Raytheon Company, Filtronetics Inc, Sora Power Inc at a specific facility of theirs. As a manufacturer of various items associated with NSN 5915013178633 , we carry a number of offerings from this CAGE Code, as well as similar parts from other manufacturers. As such, be sure to peruse our options at your leisure.
How Can I Request a Quote for Parts Produced under NSN 5915013178633 ?
  • Here on ASAP Buying, we offer customers access to a streamlined Request for Quote (RFQ) service where they can fill out and submit online forms to obtain customized options for procurement. As such, be sure to initiate the process for any parts you desire from our NSN 5915013178633 catalog, and a member of our staff will be in touch shortly after reviewing your request.

Send Instant RFQ

Guaranteed quotes back within 15 minutes, 24/7 x 365

Low Price Warrantied inventory at competitive prices
Get it fast All inventory ready to ship from our sellers
Quality guaranteed We sell only warrantied and traceable parts
Find it fast Search the world's largest inventory of electronic components by manufacturer, category or part number


 Semiconductor's Certifications and Memberships

Thank You for Visiting ASAP Buying.

Before You Go, Why Don’t You Take a Look at Our Aviation Parts Catalog.

Request for Quote

We use cookies to ensure that we give you the amazing experience on our website. If you continue to use this site we will assume that you are happy with it.