Alternative NSN: 5925-00-191-9757 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 001919757 |
NCB Code: USA (00) |
Manufacturers: Compunetics Inc, Navair And Navsea Managed, Wood Electric Operations Potter And |
Browse NSN parts of NSN 5925-00-191-9757 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5925-00-191-9757 like 109-215-101, 13-0550-150, 2812213 described as Circuit Breaker from industry leading manufactures such as Wood Electric Operations Potter And, Compunetics Inc, Navair And Navsea Managed. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
109-215-101 | Wood Electric Operations Potter And | circuit breaker | Avl | RFQ |
13-0550-150 | Compunetics Inc | circuit breaker | Avl | RFQ |
2812213 | Navair And Navsea Managed | circuitbreaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0.375 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.375 INCHES NOMINAL |
ADAT | BODY WIDTH | 0.687 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.020 INCHES NOMINAL |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.035 INCHES NOMINAL |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
CMLP | THREAD QUANTITY PER INCH | 24 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC SINGLE LOCATION AND 15.0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3000.0 AC SINGLE LOCATION AND 5000.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 135.0 SINGLE LOCATION |
CPRP | ULTIMATE TRIP TIME PER POLE IN SECONDS | 40.000 MINIMUM SINGLE LOCATION AND 200.000 MAXIMUM SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 9.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 25.000 MAXIMUM AT 200 PCT SINGLE LOCATION AND 2.500 MINIMUM AT 300 PCT SINGLE LOCATION AND 5.500 MAXIMUM AT 300 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCKPROOF AND VIBRATIONPROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 SCREW |
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |