Alternative NSN: 5925-00-443-9478 |
Item Name: Circuit Breaker |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 004439478 |
NCB Code: USA (00) |
Manufacturers: Eaton Corp, General Dynamics Corporation, L 3 Communications Corporation, Raytheon Company, Raytheon Technical Services Company, Rockwell Collins Inc, Sensata Technologies Inc |
Browse NSN parts of NSN 5925-00-443-9478 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5925-00-443-9478 like XAM333MG3-15AMP50-250VAC60CPS4, XAM333MG3-15-30, XAM333MG3-15-208AC4, XAM333M6-15-208, APL111-561-350 described as Circuit Breaker from industry leading manufactures such as Eaton Corp, Sensata Technologies Inc, Raytheon Company, Raytheon Technical Services Company, General Dynamics Corporation. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
XAM333MG3-15AMP50-250VAC60CPS4 | Eaton Corp | circuit breaker | Avl | RFQ |
XAM333MG3-15-30 | Eaton Corp | circuit breaker | Avl | RFQ |
XAM333MG3-15-208AC4 | Eaton Corp | circuit breaker | Avl | RFQ |
XAM333M6-15-208 | Eaton Corp | circuit breaker | Avl | RFQ |
APL111-561-350 | Sensata Technologies Inc | circuit breaker | Avl | RFQ |
APL-111-1-6-2-153M | Sensata Technologies Inc | circuit breaker | Avl | RFQ |
APL 111 55629 5 094 | Sensata Technologies Inc | circuit breaker | Avl | RFQ |
AM3A3A15-240AC2 | Eaton Corp | circuit breaker | Avl | RFQ |
AM333MGS-15A250VACCURVE4 | Eaton Corp | circuit breaker | Avl | RFQ |
AM333MGS-15-250VAC60C4 | Eaton Corp | circuit breaker | Avl | RFQ |
AM3-Z29-094 | Eaton Corp | circuit breaker | Avl | RFQ |
AM3-A3-15-2 | Eaton Corp | circuit breaker | Avl | RFQ |
711570-035 | Raytheon Company | circuit breaker | Avl | RFQ |
546206 | Raytheon Technical Services Company | circuitbreaker | Avl | RFQ |
29-501360-13 | General Dynamics Corporation | circuit breaker | Avl | RFQ |
271-1355P9 | Raytheon Company | circuit breaker | Avl | RFQ |
260-4011-350 | Rockwell Collins Inc | circuitbreaker | Avl | RFQ |
13MC-104-15 | Sensata Technologies Inc | circuit breaker | Avl | RFQ |
1001817-53 | L 3 Communications Corporation | circuitbreaker | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | +0.1177/+0.1214 INCHES |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.156 INCHES MINIMUM AND 2.344 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.660 INCHES MINIMUM AND 1.960 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.046 INCHES MINIMUM AND 2.078 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.719 INCHES MINIMUM AND 0.781 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.109 INCHES MINIMUM AND 0.171 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.553 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, AND THREE LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.200 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TEST | TEST DATA DOCUMENT | 81349-MIL-C-55629 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-55629/5 GOVERNMENT SPECIFICATION |
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |
Before You Go, Why Don’t You Take a Look at Our Aviation Parts Catalog.
Request for Quote