| Alternative NSN: 5925-00-491-8921 |
| Item Name: Circuit Breaker |
| FSG: 59 Electrical and Electronic Equipment Components |
| Federal Supply Class (FSC): 5925 Circuit Breakers |
| NIIN: 004918921 |
| NCB Code: USA (00) |
| Manufacturers: Eaton Corp, Westinghouse Electric Corp |
Browse NSN parts of NSN 5925-00-491-8921 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5925-00-491-8921 like EHD3035, EB3035, EB3035, 6638C90G08, 4990D03G38 described as Circuit Breaker from industry leading manufactures such as Eaton Corp, Westinghouse Electric Corp. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
| Part No | Manufacturer | Item Name | QTY | RFQ |
|---|---|---|---|---|
| EHD3035 | Eaton Corp | circuit breaker | Avl | RFQ |
| EB3035 | Westinghouse Electric Corp | circuit breaker | Avl | RFQ |
| EB3035 | Eaton Corp | circuit breaker | Avl | RFQ |
| 6638C90G08 | Eaton Corp | circuitbreaker | Avl | RFQ |
| 4990D03G38 | Eaton Corp | circuit breaker | Avl | RFQ |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 4.125 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.375 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 5.062 INCHES NOMINAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.375 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.750 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.375 INCHES NOMINAL |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.125 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 35.0 AMPERES AC ALL LOCATIONS AND 35.0 AMPERES DC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS AND 250.0 DC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS AND 5000.0 DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 28.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 75.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND DUSTPROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| PKWT | UNPACKAGED UNIT WEIGHT | 4.500 POUNDS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
|
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
|
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
|
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
|
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |
Before You Go, Why Don’t You Take a Look at Our Aviation Parts Catalog.