Alternative NSN: 5930-00-548-8057 |
Item Name: Switch Pressure |
FSG: 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 005488057 |
NCB Code: USA (00) |
Manufacturers: Northern Telecom Systems Corp |
Browse NSN parts of NSN 5930-00-548-8057 and get lowest price for your requested parts in 15 minutes. Just ordered part of NSN 5930-00-548-8057 like 555-1332, 718-0007-01 described as Switch Pressure from industry leading manufactures such as Northern Telecom Systems Corp. We are proud to offer an inventory of over 2 billion ready-to-ship parts, 24/7 availability, and key locations in the U.S./abroad. These attributes allow us to meet all aircraft on ground (AOG) requirements with ease.
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
555-1332 | Northern Telecom Systems Corp | switch pressure | Avl | RFQ |
718-0007-01 | Northern Telecom Systems Corp | switch pressure | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 3B SINGLE PRESSURE CONNECTION |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
ABHP | OVERALL LENGTH | 3.844 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
ABPM | BODY DIAMETER | 2.625 INCHES NOMINAL |
ADAQ | BODY LENGTH | 2.750 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.196 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 3.000 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | GAGE |
AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
CBBL | FEATURES PROVIDED | TAMPER PROOF CAP |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE PRESSURE CONNECTION |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQJX | NOMINAL THREAD SIZE | 0.438 INCHES SINGLE PRESSURE CONNECTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET |
CTYM | CONTACT ADJUSTMENT RANGE | +0.50/+7.00 ACTUATION POINT POUNDS PER SQUARE INCH GAGE AND +0.50/+7.00 DEACTUATION POINT POUNDS PER SQUARE INCH GAGE |
CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL DEACTUATION POINT SCREW AND INTERNAL ACTUATION POINT SCREW |
CTYX | CONTACT STIMULUS RATING | 2.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE AND 2.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SECOND VOLTAGE |
CTZL | PRESSURE CONNECTOR TYPE | GASKET SEAL, THREADED INTERNAL SINGLE CONNECTION |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | CYLINDRICAL W/MOUNTING LUGS |
THSD | THREAD SERIES DESIGNATOR | UNF SINGLE PRESSURE CONNECTION |
5905-00-001-2971 (5905000012971) |
5905-00-001-3031 (5905000013031) |
5905-00-001-3050 (5905000013050) |
5905-00-001-3085 (5905000013085) |
5905-00-001-3197 (5905000013197) |
5905-00-001-3806 (5905000013806) |
5905-00-001-3819 (5905000013819) |
5905-00-001-3821 (5905000013821) |
5905-00-001-3822 (5905000013822) |
5905-00-001-3824 (5905000013824) |
5905-00-001-3825 (5905000013825) |
5905-00-001-3827 (5905000013827) |