| Part Number: LELK11-1REC5-62-5-00-K-01 | Manufacturer: Sensata Technologies Inc |
| NSN : 5925-01-629-6145 (5925016296145) | Item Name : circuit breaker |
| CAGE Code: 81541 | FSC : 5925 Circuit Breakers |
| Alternate P/N : LELK111REC562500K01 | INC Code: 00136 |
| NIIN : 01-629-6145 (016296145) | FSG : 59 Electrical and Electronic Equipment Components |
| Country: USA | NCB Code: 01 |
Would you like to obtain a quick quote for Sensata Technologies Inc(Cage Code 81541) Part Number LELK11-1REC5-62-5-00-K-01Circuit Breakerwith NSN 5925016296145? it's just a few steps away! Simply complete the form in its entirety, and we will promptly reply with a quote within 15 minutes. This is an excellent opportunity to get the quick quote for LELK11-1REC5-62-5-00-K-01, so take advantage of it right away.
“*” Symbols for mandatory fields
ASAP Buying - an ASAP Semiconductor owned website is a leading resource to purchase national stock numbers. We have over 26 categories of distinct federal supply codes like 5925 Circuit Breakers for above part number for over 10 million national stock numbers including 5925016296145 from over 5,000 leading NSN manufacturers. Competitive prices, expedited shipping with a world class quality control and export compliance protocol are the hallmarks of our service.
A knowledgeable sale representative will contact you within 15 minutes with a quote for your required part LELK11-1REC5-62-5-00-K-01. Please feel free to call us on +1-714-705-4780 24/7 or email your Bill of Materials (BOM) to sales@asapbuying.com
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-01-629-6145 Item Description: CIRCUIT BREAKER | 5925 | 016296145 | 0 | P | A | |
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | A | 0 | |||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| LELK11-1REC5-62-5.00-K-01 | 5 | 2 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.448 INCHES NOMINAL |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 5.0 AMPERES AC ALL LOCATIONS |
| CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER |
| AKPX | Pole Quantity | 2 |
| FREQ | Frequency In Hertz | 0.051 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
| AJEC | Boss Height | 0.146 INCHES NOMINAL |
| THSD | Thread Series Designator | M |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRQ | Reset Method | MANUAL |
| AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
| ADAT | Body Width | 1.530 INCHES NOMINAL |
| ADTV | Case Material | PLASTIC |
| AJWX | Mounting Surface To Terminal End Distance | 2.546 INCHES NOMINAL |
| ADAQ | Body Length | 2.060 INCHES NOMINAL |
| AGAV | End Item Identification | CONTROL CABIN |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.940 INCHES NOMINAL |
| MRC | Decoded Requirement | Clear Text Reply |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 5.0 AC ALL LOCATIONS |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 10.0 MINIMUM AT 125 PCT AND 120.0 MINIMUM AT 125 PCT ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CQJX | Nominal Thread Size | 6.0 MILLIMETERS |