Part Number: LNS-W-15-7819 | Manufacturer: Veeco Instruments Ltd |
NSN : 6130-01-142-0122 (6130011420122) | Item Name : powersupply |
CAGE Code: 80103 | FSC : 6130 Converters Electrical Non Rotating |
Alternate P/N : LNSW157819 | INC Code: 00740 |
NIIN : 01-142-0122 (011420122) | FSG : 61 Electric Wire and Power and Distribution Equipment |
Country: USA | NCB Code: 01 |
Would you like to obtain a quick quote for Veeco Instruments Ltd(Cage Code 80103) Part Number LNS-W-15-7819Powersupplywith NSN 6130011420122? it's just a few steps away! Simply complete the form in its entirety, and we will promptly reply with a quote within 15 minutes. This is an excellent opportunity to get the quick quote for LNS-W-15-7819, so take advantage of it right away.
“*” Symbols for mandatory fields
ASAP Buying - an ASAP Semiconductor owned website is a leading resource to purchase national stock numbers. We have over 26 categories of distinct federal supply codes like 6130 Converters Electrical Non Rotating for above part number for over 10 million national stock numbers including 6130011420122 from over 5,000 leading NSN manufacturers. Competitive prices, expedited shipping with a world class quality control and export compliance protocol are the hallmarks of our service.
A knowledgeable sale representative will contact you within 15 minutes with a quote for your required part LNS-W-15-7819. Please feel free to call us on +1-714-705-4780 24/7 or email your Bill of Materials (BOM) to sales@asapbuying.com
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.000 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.875 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 5.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE SINGLE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM SINGLE OPERATING POWER RQMT AND 127.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM SINGLE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | +0.1/+71.0 DEG CELSIUS |
CBBL | FEATURES PROVIDED | FILTER |
CWGH | OUTPUT CURRENT RATING | 3.8 DC AMPERES MINIMUM SINGLE POWER OUTPUT AND 7.7 DC AMPERES MAXIMUM SINGLE POWER OUTPUT |
FEAT | SPECIAL FEATURES | FULL RECTIFICATION |